Home ] Up ] Immunology Infectious agents Cellular Biology Molecular biology Instruments Chimical Product PCR ELISA Sites Komabiotech products Product NEW antibodies NEW Cells Culturs EPIGENTEK Electrophoresis Contact Us EnoGene SACACE Albumin—OsrHSA GENTAUR NEWS Antibodies & Supporting ToolsHome ] Up ] Calcium Electrophoresis  Albumin—OsrHSA Pricelist:  http://www.diagrade.com/search.php  

Google

       Pricelist 2010 

Home
Up

OUR SUPPLIERS

KOMABIOTECH
301, Gayang Technotown, #1487 Gayang 3 dong, Gangseo-gu
Seoul 157-793, KOREA

Spherotech, Inc.
27845 Irma Lee Circle, Unit 101
Lake Forest, IL 60045

Exalpha Biologicals, Inc.
2 Shaker Road, Unit B101
Shirley, MA 01464

SCETI K.K
BIOSCIENCE
Export                                   DF Kasumigaseki Place,3-6-7 Kasumigaseki Chiyoda-ku, Tokyo 100-0013 JAPAN 

EY Laboratories, Inc. Headquarters
107 N. Amphlett Blvd
San Mateo, CA. 94401 USA

EXBIO Praha, a.s.
Nad Safinou II 366
252 42  Vestec
Czech Republic


Sacace Biotechnologies S.r.l.

Via Scalabrini, 44
22100 Como Italy

 

redcoon België GENTAUR BVBA

VAT BE0473327336

Av. de l Armee 68 B4

1040 Brussels BELGIUM

  Tel + 32 16 58 90 45 

Fax + 32 16 50 90 45

GENTAUR France SARL

SIRET 48423788800017

Rue Lagrange, 9

75005 Paris, France

 Tel 01 43 25 01 50

Fax 01 43 25 01 60 

GENTAUR Germany Marienbongard 20

52074 Aachen, Germany

Tel  0241 56 00 99 68                    Fax 0241 56 00 47 88 

GENTAUR Pol Sp. Z.o.o. Ulica Ogarna 15/19B m2

80-826 GDANSK

Tel 00 48 58 760 77 08

Fax: 00 32 16 50 90 45

GENTAUR Italy

23015 Milano, Italy

 Tel 02 36 00 65 93

Fax 02 36 00 65 94

Česká republika Praha
+420246019719
 

Danmark

+4569918806 

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494
 

Ireland Dublin
+35316526556
 

Luxembourg
+35220880274
 

Magyarország Budapest
+3619980547
 

Nederland
+31208080893
 

Norge Oslo
+4721031366
 

Österreich
+43720880899
 

Sverige Stockholm
+46852503438
 

Schweiz Züri
+41435006251
 

 

Northern America 

Canada Montreal
+15149077481
 

US New York
+17185132983

 

Other Countries redcoon België
0032 (0)16 41 44 07

 

Name Description Cat.# Category

QuantiChrom™ Calcium Assay Kit

Quantitative determination of calcium ion Ca2+ by colorimetric (612nm) method. Procedure: 3 min. Kit size: 500 tests. Detection limit: 0.08 mg/dL (20 µM). Shelf life: 12 months. Shipping: ambient temp; storage: 2-8°C.

DICA-500

Blood/urine chemistry; Cation and anion assays

 

QuantiChromTM Calcium Assay Kit (DICA-500)

Quantitative Colorimetric Calcium Determination at 612nm

DESCRIPTION

CALCIUM is measured to monitor diseases of the bone or calcium regulation disorders. Increased calcium levels in serum are reported in hyperparathyroidism, metastatic bone lesions and hypervitaminosis, while decreased levels are observed in hypoparathyroidism, nephrosis, rickets, steatorrhea, nephritis and calcium-losing syndromes. Urinary calcium levels aid the clinician in understanding how the kidneys handle calcium in certain diseases of the parathyroid gland. Urinary calcium levels are also essential in the medical evaluation of kidney stones. Simple, direct and automation-ready procedures for measuring calcium concentration in biological samples are becoming popular in Research and Drug Discovery. BioAssay Systems' calcium assay kit is designed to measure calcium directly in biological samples without any pretreatment. A phenolsulphonephthalein dye in the kit forms a very stable blue colored complex specifically with free calcium. The intensity of the color, measured at 612 nm, is directly proportional to the calcium concentration in the sample. The optimized formulation minimizes any interference by substances such as magnesium, lipid, protein and bilirubin.

KEY FEATURES

Sensitive and accurate. Use as little as 5 μL samples. Linear detection range 0.08 mg/dL (20μM) to 20 mg/dL (5mM) Ca2+ in 96-well plate assay.

Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 3 min. Can be readily automated as a high-throughput assay for thousands of samples per day.

Improved reagent stability and versatility. The optimized formulation has greatly enhanced reagent and signal stability. Cuvet or 96-well plate assay.

Low interference in biological samples. No pretreatments are needed. Assays can be directly performed on raw biological samples i.e., in the presence of lipid, protein and minerals such as magnesium, iron and zinc.

APPLICATIONS

Direct Assays: Ca2+ in serum, urine, saliva etc.

Drug Discovery/Pharmacology: effects of drugs on calcium metabolism.

Food and Beverages: calcium determination.

Environment: calcium determination in water and soil.

KIT CONTENTS (500 tests in 96-well plates)

Reagent A: 50 mL Reagent B: 50 mL

Calcium standard: 1 mL 20 mg/dL Ca2+

Storage conditions. The kit is shipped at room temperature. Store Reagent and Standard at 4°C. Shelf life of at least 6 months (see expiry dates on labels).

Precautions: reagents are for research use only. Normal precautions for laboratory reagents should be exercised while using the reagents. Please refer to Material Safety Data Sheet for detailed information.

PROCEDURES

Prepare enough working reagent by combining equal volumes of Reagent A and Reagent B. Equilibrate to room temperature before use.

Procedure using 96-well plate:

1. Dilute standards as follows. Transfer 5 μL diluted standards and samples into wells of a clear bottom 96-well plate. Store diluted standards at 4°C for future use.

2. Add 200 μL working reagent and tap lightly to mix.

3. Incubate 3 min at room temperature and read optical density at 570-650nm (peak absorbance at 612nm

Procedure using cuvette:

1. Set up test tubes for diluted standards and Samples. Transfer 15 μL diluted Standards and samples to appropriately labeled tubes.

2. Add 1000 μL working reagent and vortex to mix. Incubate 3 min. Transfer to cuvet and read optical density at 612nm.

CALCULATION

Subtract blank OD (water, #8) from the standard OD values and plot the OD against Ca2+ standard concentrations. Determine the slope using linear regression fitting. Calcium concentration of the sample is calculated as

ODSAMPLE and ODBLANK are OD612nm values of sample and sample blank (water or buffer in which the sample was diluted).

Conversions: 1 mg/dL Ca2+ equals 250 μM, 0.001% or 10 ppm.

MATERIALS REQUIRED, BUT NOT PROVIDED

Pipeting devices and accessories (e.g. 5 μL).

Procedure using 96-well plate:

Clear bottom 96-well plates (e.g. Corning Costar) and plate reader.

Procedure using cuvette:

Cuvets and Spectrophotometer for measuring OD612nm.

GENERAL CONSIDERATIONS

EDTA and other Ca2+ chelators interfere with this assay. This assay can not be applied to plasma samples obtained with EDTA.

EXAMPLES

Samples were assayed in duplicate using the 96-well plate protocol.

The Ca2+ values (mg/dL) were 8.5 ± 0.4 (rat serum), 6.5 ± 0.3 (human serum), 7.6 ± 0.1 (goat serum), 11.1 ± 1.0 (Invitrogen fetal bovine serum), 2.5 ± 0.4 (fresh human urine), 41.3 ± 0.5 (Kirkland 2% reduced fat milk), 5.0 ± 0.0 (tap water, Hayward, CA), 0.86 ± 0.07 (tap water, San Bruno, CA), 1.8 ± 0.1 (Crystal Geyser natural alpine spring water), 2.3 ± 0.1 (Coca-cola® classic coke), 0.04 ± 0.01 (Lipton Lemon iced tea), 0.52 ± 0.07 (soil extract. 5.6 g of Hayward, CA soil was extracted with 10 mL MilliQ water. The supernatant was centrifuged to remove any insoluble particles. Clear supernatant was assayed).

PUBLICATIONS

1. Carmela, T.M. et al. (2007). Bactericidal action of daptomycin against stationary-phase and nondividing staphylococcus aureus cells. Antibacterial Agents and Chemotherapy 51 (12): 4255–4260.

2. Hernandez, L. (2007). The antiproliferative role of ERG K+ channels in rat osteoblastic cells. Cell Biochem Biophys 47:199– 208.

3. Meggan, E. et al. (2007). Vitamin D receptor-dependent Inhibition of mammary tumor growth by EB1089 and ultraviolet radiation in vivo. Endocrinology 148(10):4887–4894.