Home ] Up ] Immunology Infectious agents Cellular Biology Molecular biology Instruments Chimical Product PCR ELISA Sites Komabiotech products Product NEW antibodies NEW Cells Culturs EPIGENTEK Electrophoresis Contact Us EnoGene SACACE Albumin—OsrHSA GENTAUR NEWS Antibodies & Supporting ToolsHome ] Up ] creatinine Electrophoresis  Albumin—OsrHSA Pricelist:  http://www.diagrade.com/search.php  

Google

       Pricelist 2010 

Home
Up

OUR SUPPLIERS

KOMABIOTECH
301, Gayang Technotown, #1487 Gayang 3 dong, Gangseo-gu
Seoul 157-793, KOREA

Spherotech, Inc.
27845 Irma Lee Circle, Unit 101
Lake Forest, IL 60045

Exalpha Biologicals, Inc.
2 Shaker Road, Unit B101
Shirley, MA 01464

SCETI K.K
BIOSCIENCE
Export                                   DF Kasumigaseki Place,3-6-7 Kasumigaseki Chiyoda-ku, Tokyo 100-0013 JAPAN 

EY Laboratories, Inc. Headquarters
107 N. Amphlett Blvd
San Mateo, CA. 94401 USA

EXBIO Praha, a.s.
Nad Safinou II 366
252 42  Vestec
Czech Republic


Sacace Biotechnologies S.r.l.

Via Scalabrini, 44
22100 Como Italy

 

redcoon België GENTAUR BVBA

VAT BE0473327336

Av. de l Armee 68 B4

1040 Brussels BELGIUM

  Tel + 32 16 58 90 45 

Fax + 32 16 50 90 45

GENTAUR France SARL

SIRET 48423788800017

Rue Lagrange, 9

75005 Paris, France

 Tel 01 43 25 01 50

Fax 01 43 25 01 60 

GENTAUR Germany Marienbongard 20

52074 Aachen, Germany

Tel  0241 56 00 99 68                    Fax 0241 56 00 47 88 

GENTAUR Pol Sp. Z.o.o. Ulica Ogarna 15/19B m2

80-826 GDANSK

Tel 00 48 58 760 77 08

Fax: 00 32 16 50 90 45

GENTAUR Italy

23015 Milano, Italy

 Tel 02 36 00 65 93

Fax 02 36 00 65 94

Česká republika Praha
+420246019719
 

Danmark

+4569918806 

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494
 

Ireland Dublin
+35316526556
 

Luxembourg
+35220880274
 

Magyarország Budapest
+3619980547
 

Nederland
+31208080893
 

Norge Oslo
+4721031366
 

Österreich
+43720880899
 

Sverige Stockholm
+46852503438
 

Schweiz Züri
+41435006251
 

 

Northern America 

Canada Montreal
+15149077481
 

US New York
+17185132983

 

Other Countries redcoon België
0032 (0)16 41 44 07

 

Name Description Cat.# Category

QuantiChrom™ Creatinine Assay Kit

Quantitative determination of creatinine by colorimetric (510nm) method. Procedure: 20 min. Kit size: 500 tests. Detection limit: 0.1 mg/dL (8 µM). Shelf life: 12 months. Shipping: ambient temp; storage: 4, -20°C.

DICT-500

Blood/urine chemistry

QuantiChromTM Creatinine Assay Kit (DICT-500)

Quantitative Colorimetric Creatinine Determination at 510nm

DESCRIPTION

Creatinine is synthesized in the body at a fairly constant rate from creatine, which is produced during muscle contractions from creatine phosphate. In the blood, creatinine is removed by filtration through the glomeruli of the kidney and is secreted into urine. In healthy individuals, creatinine secretion is independent of diet and is fairly constant. The creatinine clearance test has become one of the most sensitive tests for measuring glomerular filtration rate. In kidney disease, creatinine levels in the blood are elevated, whereas the creatinine clearance rate and hence the urine levels are diminished. Creatinine test is most widely used to assess kidney function. Simple, direct and automation-ready procedures for measuring creatinine concentration in biological samples are becoming popular in Research and Drug Discovery. BioAssay Systems' creatinine assay kit is designed to measure creatinine directly in biological samples without any pretreatment. The improved Jaffe method utilizes picrate that forms a red colored complex with creatinine. The intensity of the color, measured at 510nm, is directly proportional to creatinine concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw sample.

KEY FEATURES

Sensitive and accurate. Use 30 μL samples. Detection limit 0.10 mg/dL (8μM) creatinine in 96-well plate assay.

Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 5 min. Can be automated as a high-throughput assay for thousands of samples per day.

Improved reagent stability and versatility. The optimized formulation has greatly enhanced reagent and signal stability. Assays can be executed in 96-well plate or cuvet.

Low interference in biological samples. No pretreatments are needed. Assays can be directly performed on raw biological samples.

APPLICATIONS

Direct Assays: urine, serum, plasma and biological preparations.

Drug Discovery/Pharmacology: effects of drugs on creatinine metabolism.

KIT CONTENTS (500 tests in 96-well plates)

Reagent A: 50 mL Reagent B: 50 mL

Creatinine Standard: 1 mL 50 mg/dL

Storage conditions. The kit is shipped at room temperature. Store all components at 2-8°C. For long-term storage, keep standard at –20°C. Shelf life: at least 6 months (see expiry dates on labels).

Precautions: reagents are for research use only. Normal precautions for laboratory reagents should be exercised while using the reagents. Please refer to Material Safety Data Sheet for detailed information.

PROCEDURES

Equilibrate reagents to room temperature prior to use. Please note the difference in standard/sample volume and Working Reagent strength for blood and urine assays. This assay is based on a kinetic Jaffe reaction. To ensure identical incubation time, addition of Working Reagent to standard and samples should be quick and mixing should be brief but thorough. Use of a multi-channel pipettor is recommended.

Procedure using 96-well plate:

BLOOD ASSAY (LOW CREATININE LINEAR UP TO 50 mg/dL):

1. Dilute standard to 2 mg/dL by mixing 5 μL 50 mg/dL standard stock and 120 μL distilled water. Transfer 30 μL diluted standard and serum/plasma in duplicate into wells of a clear bottom 96-well plate.

2. Prepare enough Working Reagent by mixing per well reaction at least 100 μL Reagent A and 100 μL Reagent B. Add 200 μL Working Reagent quickly to all wells. Tap plate briefly to mix.

3. Read optical density immediately (OD0) and then at 5 min (OD5) at 490-530nm (peak absorbance at 510nm).

URINE ASSAY (HIGH CREATININE LINEAR UP TO 300 mg/dL):

1. Transfer 5 μL 50 mg/dL standard and urine in duplicate into wells of a clear bottom 96-well plate.

2. Prepare enough Working Reagent by mixing per well reaction 50 μL Reagent A, 50 μL Reagent B and 100 μL water. Add 200 μL Working Reagent quickly to all wells. Tap plate briefly to mix.

3. Read optical density immediately (OD0) and then at 5 min (OD5) at 490-530nm (peak absorbance at 510nm).

Procedure using cuvette:

1. Transfer 100 μL 2 mg/dL Standard and serum/plasma samples (Urine Assay: 15 μL 50 mg/dL Standard and 15 μL urine) to cuvets.

2. Prepare appropriate Working Reagent as above for the 96-well plate procedures. Add 1000 μL Working Reagent to each cuvet and pipet briefly to mix (avoid bubble formation).

3. Read OD immediately (OD0) and at 5 min (OD5) at 490-530nm.

CALCULATION

Creatinine concentration of the sample is calculated as

ODSAMPLE5, ODSAMPLE0, ODSTD5 and ODSTD0 are OD510nm values of sample and standard at 5 and 0 min, respectively. [STD] is 2 mg/dL for blood assay and 50 mg/dL for urine assay.

Conversions: 1 mg/dL creatinine equals 88.4 μM, 0.001% or 10 ppm.

MATERIALS REQUIRED, BUT NOT PROVIDED

Pipeting devices and accessories (e.g. multi-channel pipettor). Clear bottom 96-well plates (e.g. Corning Costar) and plate reader for the plate procedure. Spectrophotometer and cuvets for measuring OD 510nm for the cuvette procedure.

EXAMPLES

Samples were assayed in duplicate (n = 2) using the 96-well plate protocol. The creatinine concentration (mg/dL) was 0.38 ± 0.01 for rat serum, 0.71 ± 0.02 for rat plasma, 0.79 ± 0.00 for human serum, 0.89 ± 0.04 for human plasma, 1.20 ± 0.04 for goat serum and 136.4 ± 2.9 in a fresh human urine sample.

PUBLICATIONS

1. Wang, J.J. et al (2006). Salutary effect of pigment epithelium– derived factor in diabetic nephropathy evidence for antifibrogenic activities. Diabetes 55: 1678-1685.

2. Zhang, S.X. et al (2006). Therapeutic potential of angiostatin in diabetic nephropathy. J Am Soc Nephrol 17: 475–486.